Turn on delay: 5,10,15,30,90,180 secs |
Working Voltage: 230V,50Hz,Maximum Current: 13A |
Default: Low voltage 140V, High voltage 250V, Wait time 15secs |
High Voltage range: 230V-280V |
Low Voltage range: 140V-220V |
Shell:Fireproof PC |
Plug:Brass |
Socket Shrapnel:Phosphor bronze |
Universal socket,UK plug |
Child protection socket |
One year warranty |
Operating instructions: Press buttion "BY-PASS" within the voltage allowable range to turn on the power immediately without waiting for a delay. 1.Set up high cut voltage:press button "H" to get your needed high voltage,then press "BY-PASS" to confirm,system will work as new setting.Adjustable range:230-280 volts. 2.Set up low cut voltage:press button "L" to get your needed low voltage,then press "BY-PASS" to confirm,system will work as new setting.Adjustable range:140-220 volts. 3.Set up delay time:press button "Wait Time" to get your needed delay time,then press "BY-PASS" to confirm,system will work as new setting.Adjustable range:5-180 seconds. |